Bosch Appliances Combinación de DVD de televisión E2600 Manual del usuario

E2600 DSA E-Series iSCSI Disk Arrays  
en Quick Install Guide  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
E2600 DSA E-Series iSCSI Disk Arrays  
Table of Contents | en  
3
Table of contents  
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
4
en | Before you begin  
E2600 DSA E-Series iSCSI Disk Arrays  
1
Before you begin  
For warnings and detailed installation instructions, refer to the E2600 DSA E-Series  
Installation manual and additional documentation in the Online Product Catalog on http://  
www.boschsecurity.com > Video > Digital Recording and Storage > Disk Arrays (Network  
Attached) > DSA – Disk Arrays > DSA E-Series iSCSI Disk Arrays. (The navigation path is  
subject to change).  
Management methods are specific to the installation steps in Section 6 and Section 9.  
1.1  
Learn about management methods  
In-band management  
Management using the I/O connections between the host and the storage. The host must still  
have Ethernet capabilities.  
Access volume  
Used to communicate management requests and event information. An access volume is  
needed for only in-band management.  
Out-of-band management  
Management directly through the Ethernet connections on each controller using one of the  
network configurations from the following list (the command line interface CLI might be  
required):  
DHCP server  
Permits nodes to dynamically acquire network addresses.  
Ethernet IP address  
Permits direct connection to controller A or controller B by using an IP address in the  
form of xxx.xxx.xxx.yyy and xxx.xxx.xxx.yyz.  
Static IP address  
Recommended for out-of-band management using IPv4 networks.  
Router advertisements  
Recommended for out-of-band management using IPv6 networks.  
MAC address  
Associates the media address control (MAC) address (xx:xx:xx:xx:xx:xx) of each controller  
with an assigned IP address.  
1.2  
What you need for assembly  
E2600 controller-drive tray ship group  
One two-unit (2U) -high E2600 controller-drive tray  
Two power cords  
One cabinet mounting hardware kit, including:  
Two mounting rails (right and left assemblies)  
Eight M5 x 8 mm screws – Use six screws to secure the mounting rails and two  
screws to secure the front of the controller-drive tray to the cabinet.  
Two M4 x 8 mm screws – Use the screws to secure the rear of the controller-drive  
tray to the mounting rails.  
Options  
Drives (two minimum for each controller-drive tray)  
DC power cords for the optional –48 VDC power option  
If you have any questions about the firmware or your configuration, contact your Customer  
and Technical Support representative.  
Tools  
An Internet connection  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
     
E2600 DSA E-Series iSCSI Disk Arrays  
Before you begin | en  
5
A cart to hold the controller-drive tray and its components  
Labels for the cable connections  
A medium flat-blade screwdriver  
A No. 2 Phillips screwdriver  
Anti-static protection  
A flashlight  
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
6
en | Device view  
E2600 DSA E-Series iSCSI Disk Arrays  
2
Device view  
Controller-Drive Tray (12 Drives) – Front View  
1
2
3 4  
5
6
!
Figure 2.1: Front View E2600  
1
2
3
Standby Power LED  
Power LED  
4
5
6
Service Action Required LED  
Locate LED  
Over-Temperature LED  
Drive Canister  
Controller-Drive Tray – Rear View  
1
2
Figure 2.2: Rear View E2600  
1
Controller Canister  
2
Power-Fan Canister  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
E2600 DSA E-Series iSCSI Disk Arrays  
Install the mounting rails | en  
7
3
Install the mounting rails  
You can install the drive tray into an industry-standard cabinet.  
There must be a minimum depth of 76 cm (30 in.) between the front EIA support rails and the  
rear EIA support rails.  
1. Position the mounting rails in the cabinet.  
If you are installing the mounting rails above an existing tray, position the mounting  
rails directly above the tray.  
If you are installing the mounting rails below an existing tray, allow 8.9-cm (3.5-in.)  
vertical clearance for the controller-drive tray.  
2. Starting with the left mounting rail, use a flat-blade screwdriver to loosen the two flat-  
head rail adjustment screws. Hold the front of the left mounting rail against the inside of  
the front cabinet-mounting flange, and then extend the rear of the mounting rail until it  
makes contact with the rear cabinet-mounting flange. The alignment pins at the rear of  
the mounting rail should slide into the holes at the rear of the cabinet.  
1
2
1
4
3
Figure 3.1: Mounting Rails  
1
2
3
4
Mounting Holes on the Industry-Standard Cabinet  
Adjustment Screws for Locking the Length of the Mounting Rail  
Mounting Rail  
Clip for Securing the Rear of the Controller-Drive Tray  
3. From the front of the cabinet, with the mounting-rail flanges inside of the cabinet’s  
mounting rail assemblies, use the Phillips screwdriver to loosely tighten only the lower  
screw.  
4. From the rear of the cabinet, use the Phillips screwdriver to loosely tighten the two  
screws. Do not completely tighten the screws until you have installed the controller-drive  
tray in the cabinet.  
5. Repeat step 1 through step 4 for the right mounting rail.  
6. Tighten the fl at-head rail adjustment screws on both mounting rails.  
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
8
en | Install the controller-drive tray  
E2600 DSA E-Series iSCSI Disk Arrays  
4
Install the controller-drive tray  
Warning!  
Risk of bodily injury  
!
,
Two persons are required to safely lift the component.  
1. With the help of one other person, remove the controller-drive tray from the shipping box.  
2. With the help of one other person, slide the rear of the controller-drive tray onto the  
mounting rails so that the mounting holes on the front flanges of the controller-drive tray  
align with the mounting holes on the front of the mounting rails.  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
E2600 DSA E-Series iSCSI Disk Arrays  
Secure the controller-drive tray | en  
9
5
Secure the controller-drive tray  
Warning!  
Risk of bodily injury  
Do not use equipment in the cabinet as a shelf or work space.  
!
1. Secure the screws in the top mounting holes and the bottom mounting holes on each  
side of the controller-drive tray.  
2
1
2
1
Figure 5.1: Controller-Drive Tray (12 Drives)  
1
Mounting Holes  
2
Screws  
2. Secure the rear of the controller-drive tray to the cabinet by using two screws to attach  
the flanges on each side at the rear of the controller-drive tray to the mounting rails.  
3. Install the front end caps on the front of the controller-drive tray by pressing the front  
end caps into place on the left side and the right side.  
Note:  
You will install the DE1600 drive trays below and above the controller-drive tray, keeping  
the weight in the lower portion of the cabinet. You can install a maximum of 192 drives,  
including the 12 drives in the E2600 controller-drive tray. If needed, refer to E2600  
Controller-Drive Tray Installation manual.  
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
10  
en | Connect the cables  
E2600 DSA E-Series iSCSI Disk Arrays  
6
Connect the cables  
Warning!  
Risk of exposure to laser radiation  
!
Do not disassemble or remove any part of a Small Form-factor Pluggable (SFP) transceiver  
because you might be exposed to laser radiation.  
In this step, you will connect the E2600 controller-drive tray to the host or hosts, and then you  
will connect the DE1600 drive tray to either a E2600 controller-drive tray (which contains the  
controllers), or to another DE1600 drive tray in the storage array.  
For more information, refer to these documents:  
DE1600 Drive Tray Quick Install Guide  
E2600 Installation manual  
You can find the E2600 Controller-Drive Tray Installation manual and additional documentation  
and Storage > Disk Arrays (Network Attached) > DSA – Disk Arrays > DSA E-Series iSCSI Disk  
Arrays. (The navigation path is subject to change).  
Host-to-Controller Cabling  
1. Attach the appropriate cables and components for the relevant protocol (Fibre Channel,  
SAS, or Ethernet).  
2. Choose the host connection configuration (examples follow).  
Direct topology  
Connect the cable from the host port on the controller to either an HBA port, a SAS  
port, a host channel adapter (HCA) Fibre Channel port, or an Ethernet adapter  
(iSCSI) on the host. The fi gures on the next page all show the HBA port option on  
the host.  
Switch or fabric topology  
Connect the cable from the host port on the controller to a port on the switch, and  
make sure that the HBA and the controller are in the same zone on the switch.  
Mixed topology  
Use a combination of direct topology and fabric topology.  
3. Repeat step 1 through step 2 for each controller and host channel that you intend to use.  
4. When you are finished, label each end of the cable with information about its connection.  
Direct Topology – Two Hosts and a Dual Controller-Drive Tray for Maximum  
Redundancy  
(For more examples of a switch or fabric topology or of a mixed topology, refer to E2600  
Installation manual)  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
E2600 DSA E-Series iSCSI Disk Arrays  
Connect the cables | en  
11  
1
1
2
3
2
3
4
5
4
5
6
7
5. Cable the drive trays as needed. For maximum redundancy and tray loss protection, see  
the following figure. Refer to Hardware Cabling for detailed information.  
Note:  
The number of drive trays may vary as long as the maximum number of drives is not  
exceeded.  
You can connect a combination of drive trays for a maximum of 192 drives, including  
the 12 drives in the E2600 controller-drive tray.  
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
12  
en | Connect the cables  
E2600 DSA E-Series iSCSI Disk Arrays  
Contr oller A  
Contr oller B  
Exp  
Exp  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
SAS EXP  
SAS EXP  
SAS EXP  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
SAS EXP  
SAS EXP  
SAS EXP  
SAS EXP  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
SAS IN SAS IN  
ESM A  
SAS IN SAS IN  
ESM B  
SAS EXP  
Steps to connect Ethernet cables for out-of-band management only  
1. Connect one end of the Ethernet cable to the Ethernet port 1 connector on controller A.  
2. Connect the other end of the Ethernet cable to the appropriate Ethernet network  
connection or directly to your Ethernet ports on your management station.  
3. Repeat step 1 through step 2 for controller B.  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
E2600 DSA E-Series iSCSI Disk Arrays  
Turn on the DC power | en  
13  
7
Turn on the DC power  
Notice!  
DC power is an option that is available for use with your E2600 controller-drive tray and drive  
trays. If you choose to have –48 VDC power available, you need a qualified service person to  
install the equipment that provides special DC power connectors to each power-fan canister  
in your storage array.  
Warning!  
Risk of bodily injury  
!
A qualified service person is required to make the DC power connection according to NEC  
and CEC guidelines.  
Warning!  
Risk of electrical shock  
This unit has more than one power source. To remove all power from the unit, all DC MAINS  
must be disconnected by removing all power connectors (item 4 below) from the power sup-  
plies.  
!
+
-
1
2
3
4
Figure 7.1: Power cable  
1
2
Supply (Negative), Brown Wire, –  
48 VDC  
3
4
Ground, Green/Yellow Wire  
DC Power Connector  
Return (Positive), Blue Wire  
Warning!  
Risk of bodily injury  
Each tray has more than one power cord. To remove all electrical current from the devices,  
make sure that all of the power cords are disconnected from the power source and that the  
two-pole 20-amp circuit breaker for the storage array has been disconnected.  
!
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
14  
en | Turn on the DC power  
E2600 DSA E-Series iSCSI Disk Arrays  
2
1
You must follow the power sequence in the order shown. To establish power redundancy for  
trays with two power supplies, use a separate power source for each power-fan canister. For  
additional redundancy, you can connect each DC power connector on the same power-fan  
canister to a different power source.  
Notice!  
You must turn on the power to all connected drive trays before you turn on the power to the  
E2600 controller-drive tray. Performing this action makes sure that the controllers recognize  
each attached drive tray.  
1. Disconnect the two-pole 20-amp circuit breaker for the storage array  
2. Make sure that all of the DC Power switches on the DC-powered controller-drive tray and  
the DC-powered drive trays are turned off.  
3. Connect the DC power connector cables to the DC power connectors on the rear of the  
controller-drive tray and the drive trays.  
4. Have a qualifi ed service person connect the other end of the DC power connector cables  
to the DC power plant equipment.  
5. Turn on the Power switch on each power-fan canister in all of the drive trays.  
6. Turn on the Power switch on each power-fan canister in the controller-drive tray.  
Note:  
When turning off the power to the storage array, perform the procedure in the reverse  
order. Turn off the power first to the controller-drive tray, and then turn off the power to  
the drive trays.  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
E2600 DSA E-Series iSCSI Disk Arrays  
Turn on the AC power | en  
15  
8
Turn on the AC power  
2
1
You must follow the power sequence in the order shown for turning on AC power to  
controller-drive trays and drive trays that use AC power. To establish power redundancy for  
trays with two power supplies, use at least two different power distribution units (PDUs) in  
the cabinet. Split the power connections from each tray into the separate PDUs. Then connect  
the PDUs to external power receptacles that are on different circuits.  
Warning!  
Risk of bodily injury  
!
Each tray has more than one power cord. To remove all electrical current from the devices,  
make sure that all of the power cords are disconnected from the power source.  
Notice!  
You must turn on the power to all connected drive trays before you turn on the power to the  
E2600 controller-drive tray. Performing this action makes sure that the controllers recognize  
each attached drive tray.  
1. Turn off all of the Power switches from the rear of the storage array, and make sure that  
all of the power cords are connected.  
2. If the main AC circuit breaker switches in the cabinet are not already turned on, turn on  
the circuit breaker switches.  
3. Turn on the Power switch on each power-fan canister in all of the installed drive trays.  
4. Turn on the Power switches on each power-fan canister in the E2600 controller-drive tray.  
Note:  
When turning off the power to the storage array, perform the procedure in the reverse  
order. Turn off the power fi rst to the controller-drive tray, and then turn off the power to  
the drive trays.  
Bosch Sicherheitssysteme GmbH  
Quick Install Guide  
07/2012 | V1 |  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
16  
en | Install and configure the storage array  
E2600 DSA E-Series iSCSI Disk Arrays  
9
Install and configure the storage array  
For the basic setup use the VRM Configuration Manager software. For detailed information  
refer to the Configuration Manager operating manual.  
For advanced features refer to the SANtricity configuration and installation manual.  
All necessary documentation can be found in the Online Product Catalog on http://  
www.boschsecurity.com > Video > Digital Recording and Storage > Disk Arrays (Network  
Attached) > DSA – Disk Arrays > DSA E-Series iSCSI Disk Arrays. (The navigation path is  
subject to change).  
07/2012 | V1 |  
Quick Install Guide  
Bosch Sicherheitssysteme GmbH  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
 
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  
Bosch Sicherheitssysteme GmbH  
Robert-Bosch-Ring 5  
85630 Grasbrunn  
Germany  
© Bosch Sicherheitssysteme GmbH, 2012  
Descargar from Www.Somanuals.com. All Manuals Search And Descargar.  

Black Decker Crib VG085 Manual del usuario
Blaupunkt Sistema estereofónico automotriz C32 Manual del usuario
Bogen Accesorios de videojuegos SPS2454 Manual del usuario
Bosch Appliances DVR DVR 440 Manual del usuario
Bosch Appliances Amplificador estereofónico LBB 1925 10 Manual del usuario
Bose Headphones AE2i Manual del usuario
Bush Hog Compact Loader 1747 Manual del usuario
Campbell Hausfeld Compresor de aire HM7510 Manual del usuario
Canon Flash de la Cámara 2805B002 Manual del usuario
Canon Impresoras fotográficas IP3500 Manual del usuario